710C0031 / 710C0001
PA6, unfilled
Typical parts: Air filter lids and hinges
Polyamide 6 and 66
The engineering workhorse.
Tough, wear-resistant and heat-resistant, with glass-fibre reinforcement raising stiffness and strength and halving thermal expansion. Unfilled to 60% glass fibre, mineral and hybrid fillers, super-tough, heat-stabilised and flame-retardant.
Typical parts
Polyamide 6 is the most widely specified engineering thermoplastic for good reason: toughness, wear resistance, chemical resistance and heat resistance in one easily moulded polymer. CiLON® PA6 grades add glass fibre, minerals and hybrid fillers: reinforced grades are up to 80% stiffer and 70% stronger than unfilled PA6, with roughly half the thermal expansion.
Compared with PA66, PA6 gives better surface finish, easier processing and higher impact strength at a lower melt temperature; PA66 gives higher stiffness and heat resistance.
What it offers
PA6, unfilled
Typical parts: Air filter lids and hinges
PA6, unfilled, super tough
PA6, unfilled, cable-tie grade
Typical parts: Cable ties
PA6, 15% glass fibre
PA6, 25% glass fibre
PA6, 25–30% glass fibre, high flow, heat-stabilised
Typical parts: Engine covers, fan shrouds
PA6, 30% glass fibre
Typical parts: Air intake manifolds, air filter housings, power-tool housings
PA6, 40% glass fibre
PA6, 50% glass fibre
Typical parts: Metal replacement, structural parts
PA6, 60% glass fibre
Typical parts: Metal replacement, structural parts
PA6, 40% mineral filled, low warpage
PA6, 15% glass fibre + 15% mineral hybrid
PA6 absorbs moisture in service, gaining toughness and losing stiffness. Validate parts conditioned to ISO 1110, not dry-as-moulded.
A mould at 80–90 °C improves crystallinity and hides fibre read-out on visible surfaces; cooler tools shorten cycle but raise post-shrinkage.
Glass–mineral grades such as 710C3301 reduce differential shrinkage and warpage on flat, thin housings and covers.
Where the application runs hotter, stiffer and longer, polyamide 66 is the answer. Its higher melting point and crystallinity give better creep resistance, higher heat-deflection temperature and lower moisture-driven property change than PA6. CiLON® PA66 grades cover unfilled and super-tough materials through 60% glass fibre, with heat-stabilised, hydrolysis-resistant and high-flow variants for the engine bay.
Heat-stabilised (HS) grades are formulated for long-term thermal ageing; hydrolysis-resistant (HR) grades retain properties after ageing in hot glycol coolant.
What it offers
PA66, unfilled, super tough
PA66, unfilled, heat-stabilised
Typical parts: Cable ties on engine-bay routings
PA66, unfilled, cable-tie grade
Typical parts: Cable ties
PA66, 30% glass fibre
Typical parts: Air filter housings
PA66, 30% glass fibre, heat-stabilised
Typical parts: Radiator end tanks, cooling pipes
PA66, 30% glass fibre, hydrolysis-resistant, heat-stabilised
Typical parts: Radiator end tanks, cooling pipes and connectors
PA66, 30% glass fibre, high flow, heat-stabilised
Typical parts: Engine and cylinder-head covers
PA66, 33% glass fibre
PA66, 35% glass fibre
PA66, 35% glass fibre, heat-stabilised
Typical parts: Cylinder-head covers, under-hood structural parts
PA66, 35% glass fibre, high flow, heat-stabilised
Typical parts: Thin-wall, laser-welded intake manifolds
PA66, 50% glass fibre
Typical parts: Metal replacement, structural parts
PA66, 60% glass fibre
Typical parts: Metal replacement, structural parts
PA66, 40% mineral filled, low warpage
PA66 melts near 260 °C and degrades above 300 °C: keep residence time short and purge on every stop.
Specify heat-stabilised grades for continuous service above about 120 °C or where thermal ageing is specified.
Dry to 0.1% moisture and run glass-reinforced grades in an 80–100 °C mould; splay is the first sign of wet material.
Miniature circuit breakers, contactors, terminal blocks and wiring devices need a polymer that will not sustain a flame, resists tracking under voltage and holds its shape and strength through years of service. Flame-retardant polyamide grades are formulated for exactly that: unfilled and reinforced, in the greys and light colours the industry expects.
Grades are developed against UL 94, glow-wire (IEC 60695-2-12 and -13) and CTI (IEC 60112) requirements; ratings and test thicknesses are given on each grade's data sheet.
What it offers
PA6, 20% glass fibre, flame retardant
PA6, 30% glass fibre, flame retardant
Typical parts: Contactor and relay housings
PA66, 15% glass fibre, flame retardant
PA66, 20% glass fibre, flame retardant
PA66, 30% glass fibre, flame retardant
Typical parts: Contactor and relay housings
FlamSaf® grades for breaker housings
UL 94 and glow-wire results depend on thickness. Confirm the rating at the part's minimum wall.
Flame-retardant packages narrow the processing window: keep melt temperature and residence time down, and avoid hot-runner dead spots.
Flame-retardant fillers shift the base colour. Match greys and whites against a plaque of the FR grade, not the natural grade.
| Family | Drying | Max. moisture | Melt temperature | Mould temperature |
|---|---|---|---|---|
| CiLON® / eCiLON® PA6 | 80 °C, 4–6 h | ≤ 0.10% | 240–270 °C | 60–90 °C |
| CiLON® / eCiLON® PA66 | 80 °C, 4–6 h | ≤ 0.10% | 275–295 °C | 70–100 °C |
Starting points for standard reinforced grades. The grade data sheet and, where issued, the product-specific processing sheet take precedence: flame-retardant, high-flow and alloy grades run in narrower windows.
A free 25 kg trial lot compounded on production lines, and a Calco engineer at your press.