The problem
Lot-to-lot variation stops the line
Each new lot means resetting the press and sorting parts.
Colour off the plaque
A whole range can be rejected on ΔL alone.
A change nobody told you about
An uncontrolled process change becomes an audit non-conformance, and traceability is lost.
The impact
Rejects, resetting and downtime at the moulder; non-conformances and lost traceability at the OEM.
The solution
What we do about it.
Retained references
Reference granulate and colour standards are retained for each grade, so a batch can be reproduced, and compared, at any time.
A certificate with every lot
Measured values against specification limits for each production lot, issued with the delivery.
Colour held to ΔE ≤ 0.5
Colour held lot to lot, measured on every lot, and built against your own plaque.
The trial is the series
Development batches are compounded on the same equipment as production lots, so what you approve on the trial is what you receive in series.
No silent changes
Management of change, QA-approved labels and 4M records. Once your grade is approved, it stays the grade you approved.
The evidence
The release windows, grade by grade.
These are the windows in Calco's inspection standards for the breaker range. Every lot is tested against them before dispatch, so they are conservative compared with typical data-sheet values.
| Grade | Construction | UL 94 | HDT °C | Tensile MPa | Flex mod. GPa | Density g/cc |
|---|---|---|---|---|---|---|
| 710C2383F4 | PA6, 20% mineral + 5% glass fibre, flame retardant | V-2 | ≥ 150 | 60–80 | 4.5–5.5 | 1.35–1.41 |
| 710C2383F2 | PA6, mineral + glass fibre, flame retardant | V-2 | ≥ 150 | 60–90 | 3.0–4.0 | 1.34–1.38 |
| 710C2383F2A | PA6, mineral + glass fibre, flame retardant, high flow | V-2 | ≥ 150 | 60–70 | 5.0–6.5 | 1.34–1.38 |
| 710C2283F4 | PA6, 20% mineral, flame retardant | V-2 | 135–145 | 65–75 | 4.0–6.0 | 1.31–1.35 |
| 710C2082F1 | PA6, 20% glass fibre, flame retardant | V-0 | 180–190 | 110–130 | 3.5–5.5 | 1.38–1.42 |
| 710D2011F | PA6, 25% reinforced, flame retardant | V-2 | 185–195 | 105–130 | 3.5–5.5 | 1.29–1.33 |
| 730C3381F | PBT, 30% glass fibre, flame retardant | V-0 | 190–200 | 80–100 | 6.0–8.0 | 1.62–1.67 |
| 730C3083F1 | PBT, 30% glass fibre, flame retardant | V-0 | 190–200 | 100–120 | 6.0–10.0 | 1.62–1.66 |
| 730C3085F1 | PBT, 30% glass fibre, flame retardant | V-0 | 180–200 | 100–120 | 5.0–7.0 | 1.62–1.66 |
Test methods: ASTM D638 (tensile at yield, 50 mm/min), ASTM D790 (flexural, 2 mm/min), ASTM D648 (HDT, 1.82 MPa, un-annealed), ASTM D792 (density); UL 94 at 3.2 mm. Source: Calco inspection standards. Values are specification windows and are not a guarantee of properties in a finished part.
What an OEM audit found.
12 of 12 audit points closed
A switchgear OEM qualified the plant, not only the pellet. Nine of twelve audit points were closed on the day and three process points within the month.
Traceable bags
QA-approved labels link each bag to its lot and test certificate.
4M records
Man, machine, material and method recorded for production lots.
Ask for the inspection standard of a grade.
An application engineer replies with a recommended grade, the data behind it and a free 25 kg trial lot.