A traction battery is an electrical cabinet on wheels: hundreds of cells held in insulating frames, busbars carried on insulators, connectors that must never track, and housings that must not burn. The material set is flame-retardant, high-CTI, dimensionally stable and, for anything the service technician must recognise as high voltage, reliably orange.
What the material must deliver.
Flame retardancy
Flame-retardant grades rated UL 94 V-0 at the part's minimum wall, in halogen-free systems where OEM requirements exclude halogens.
Tracking resistance
CTI of 600 V or more (PLC 0) allows compact creepage distances in 400 V and 800 V architectures.
Heat and thermal-event resistance
Heat-stabilised grades that keep insulation and structure through pack operating temperatures and short thermal excursions.
Colour and identification
Orange colour-matched to RAL 2003 or the OEM standard, with colour stability after heat ageing; laser-markable for traceability.
Our recommendation, application by application.
| Application | Our recommendation | Grades to start from | Family | Status |
|---|---|---|---|---|
| Battery-module end plates and frames | PA66 GF30–35 FR, PBT GF30 FR: V-0 structure under cell compression | 720C3001F721C3005F730C3001F | CiLON® eCiLON® ZiLITE® | In development |
| Cell holders and spacers | PC/ABS FR, PBT GF FR: thin-wall V-0 insulation | 760C6081F730C3031F | PiCAN® ZiLITE® | In development |
| Busbar carriers and insulators | PA66 GF30 FR, PBT GF30 FR, orange: CTI of 600 V or more for creepage | 720C3001F730C3031F | CiLON® ZiLITE® | In development |
| High-voltage connector housings and covers | PBT GF30 FR, PA66 GF30 FR, orange: tracking and latch retention | 730C3001F720C3001F | ZiLITE® CiLON® | In development |
| Charging inlets and sockets | PBT GF30–50 FR, UV-stabilised: V-0, weathering, stiffness | 730C3001F730C5001F | ZiLITE® | In development |
| BMS, junction-box and controller housings | PC/ABS FR, FR PC: V-0 with impact and flow | 760C6081F750C0031F | PiCAN® | In development |
| High-voltage harness clips, ties and conduits, orange | PA66 unfilled HS, PA6 unfilled, orange: identification, heat routing | 720C0001HS710C0001 | CiLON® | In development |
| Battery trays and pack covers, low-voltage side | PP GF30, PA6 GF30: stiffness, acid resistance, cost | 500C3001710C3001 | HiLENE® CiLON® | Ready to specify |
In production: grades in series supply for the named part. Ready to specify: validated grades with data sheets and trial quantities available; part-specific validation is run with you. In development: grades, colours and references being built with OEM and Tier-1 partners.
Design and development notes.
Specify the electrical test set
Agree UL 94 thickness, CTI class, dielectric strength and glow-wire requirements before the grade is chosen; they drive the flame-retardant package.
Orange is a formulation, not a paint
Orange flame-retardant grades are colour-matched on the FR base and validated for colour hold after heat ageing; agree the standard plaque early.
Thin walls, long flow
Cell holders and carriers are large, thin and heavily ribbed; high-flow flame-retardant grades and hot-runner layouts that avoid dead spots keep the rating and the cycle.
The rest of the growth programme.
Supplied under IATF 16949.
PPAP documentation, IMDS material data and a test certificate with every lot.