Calco Poly Technik

Home / Solutions / Pass glow-wire and UL 94 at a thin wall

Rated at the wall you mould, not the bar on the data sheet.

UL 94 and glow-wire results depend on thickness. We test at your thinnest wall before the trial, so the type test confirms what you already know.

The problem

  • The rating only holds at 3.2 mm

    A rating on a 3.2 mm test bar says little about a 0.8 mm wall.

  • Glow-wire at a loose terminal

    Parts that hold live terminals are tested at 960 °C. A material that sustains a flame turns a fault into a fire.

  • Tracking between terminals

    Dust and humidity turn a marginal material into leakage and nuisance tripping.

The impact

A type test that fails after the tool is cut, a launch that slips, and in the field a fire that spreads pole to pole across the board.

The solution

What we do about it.

Tested at your wall

Rated and verified at 0.8 mm. In an OEM head-to-head trial at 0.8 mm, a Calco grade passed GWFI 960 °C and UL 94 V-2 where the incumbent material failed.

Built for 960 °C

Flame-retardant systems built for glow-wire 960 °C at thin walls: 960 °C GWFI at 1.6 and 3 mm in UL tests.

High tracking resistance

450 V CTI and 33.9 kV/mm dielectric strength on 30% glass FR PBT, third-party tested and witnessed by the OEM.

Colour built on the FR base

Matched against your plaque: ΔL, Δa and Δb within 0.8, checked again after ageing.

Rated where it fails.

A rating on a 3.2 mm test bar says little about a 0.8 mm wall. Bars are drawn to scale.

3.2 mmUL test bar: what data sheets quote
1.5 mmtypical MCB housing wall
0.8 mmwhere global OEMs now rate, and where we test

The temperature ladder.

Drag the temperature to see the typical requirement at each step for parts in a breaker.

960°C

960 °C: glow-wire flammability for parts holding live parts in position.

Start from the requirement.

Electrical parts are specified by test, not by polymer. The table matches common requirement sets to the grades usually chosen. Ratings, test thicknesses and colours are confirmed on the grade data sheet.

RequirementMaterial directionGrades to start fromFamily
MCB and MCCB housings, glow-wire 960 °C, light greyMineral-filled or glass–mineral FR PA6710C2383F4710C2081F710C3084FFlamSaf® CiLON®
Terminal blocks and wiring devices, unfilled, light coloursUnfilled halogen-free FR PA6 or PA66710C0031F720C0031FFlamSaf®
Contactor and relay housings, reinforced, V-030% GF FR PA6 or PA66, or 30% GF FR PBT710C3001F720C3001F730C3031FCiLON® ZiLITE®
Connector housings, thin wall, low warpage, V-030% GF FR PBT730C3031F730C3001F730C3391FZiLITE®
Lamp holders and bases, whiteGF PBT and FR PBT, white730C2093730C3391F730C3092FZiLITE®
Appliance and electrical housings in PP, V-0Unfilled, talc- or mineral-filled FR PP500C0031F500C2131F500C3131FHiLENE®
Electrical enclosures and LED housings, impact and V-0FR PC and FR PC/ABS750C0031F760C6081F760C3001FPiCAN®
Recycled-content parts with a fire ratingGF FR eCiLON® PA6 or PA66711C2001F711C3001F721C3005FeCiLON®

The tests behind the specification.

UL 94: flammability

Vertical burn classes V-0, V-1 and V-2 and horizontal HB, at a stated thickness. Thinner walls are harder to pass; specify the rating at the part's minimum wall.

Glow-wire: IEC 60695-2-12 and -13

GWFI is the temperature at which the material does not sustain a flame after glow-wire contact; GWIT the temperature at which it does not ignite. Unattended appliances and switchgear typically call for GWFI 960 °C and GWIT 750 °C or 775 °C.

CTI: IEC 60112

The comparative tracking index rates resistance to surface tracking under voltage and contamination. Higher CTI (PLC 0–1) allows smaller creepage distances and more compact designs.

Halogen-free or halogenated

Halogen-free systems give low smoke and corrosivity and meet customer requirements that go beyond RoHS; halogenated systems can offer lower cost and easier light colours.

The number your part has to hit.

The product standard, not the material data sheet, sets the glow-wire temperature.

ProductStandardParts holding live partsOther insulating parts
Miniature circuit breakersIEC 60898-1960 °C650 °C
RCCBs and RCBOsIEC 61008-1 / 61009-1960 °C650 °C
LV switchgear, contactors, MCCBsIEC 60947-1 / -2 / -4-1960 °C650 °C
Terminal blocksIEC 60947-7-1960 °C650 °C

Values summarise the usual requirement. Confirm against the current edition and clause of the standard your product is certified to.

Three things that decide the result at the press.

Ask for the rating at your wall

UL 94 and glow-wire results depend on thickness. Confirm the rating at the part's minimum wall.

Run at the low end

Flame-retardant packages narrow the processing window: keep melt temperature and residence time down, and avoid hot-runner dead spots.

Agree colour on the FR base

Flame-retardant fillers shift the base colour. Match greys and whites against a plaque of the FR grade, not the natural grade.

Send us the standard and the wall thickness.

An application engineer replies with a recommended grade, the data behind it and a free 25 kg trial lot.

Request a sample