620D3031
Modified PPE, 30–35% glass fibre, hydrolysis and glycol resistant
Typical parts: Radiator end tanks, cooling pipes, fan shrouds
Modified polyphenylene ether
For hot coolant, steam and dimensions that must not move.
Modified PPE absorbs almost no water, holds its dimensions across humidity and temperature, and shrugs off hot glycol coolant and steam that would hydrolyse polyamide or PBT. NovaLYN™ brings those properties to glass-reinforced compounds for cooling-system, fluid-handling and battery-system parts, with the lowest density in the engineering-polymer range.
Typical parts
NovaLYN™ is the newest Calco family. Additional reinforcement levels, unfilled and flame-retardant grades are in development; ask us for the current range.
What it offers
Modified PPE, 30–35% glass fibre, hydrolysis and glycol resistant
Typical parts: Radiator end tanks, cooling pipes, fan shrouds
Polyamide loses strength after long exposure to hot glycol; mPPE does not hydrolyse. For end tanks and pipes with a 15-year life, that difference decides the material.
With near-zero moisture uptake, mPPE parts measure the same conditioned as dry: useful where crimp seals, quick-connects and gaskets depend on geometry.
At roughly 10% lower density than glass-reinforced PA66, NovaLYN™ parts are lighter at equal wall thickness.
Fuels, oils and aromatic solvents attack mPPE; for intake, fuel and oil-side parts, CiLON® polyamide remains the right choice.
| Family | Drying | Max. moisture | Melt temperature | Mould temperature |
|---|---|---|---|---|
| NovaLYN™ mPPE | 100 °C, 2–4 h | ≤ 0.05% | 280–310 °C | 80–110 °C |
Starting points for standard reinforced grades. The grade data sheet and, where issued, the product-specific processing sheet take precedence: flame-retardant, high-flow and alloy grades run in narrower windows.
A free 25 kg trial lot compounded on production lines, and a Calco engineer at your press.