Calco Poly Technik

Home / Industries / Circuit protection

Flame-retardant compounds for every breaker you build.

MCB, RCCB, RCBO, isolator, MCCB, contactor and distribution-board parts. In series with switchgear makers since 2023, with every trial on their presses on record.

960 °Cglow-wire on parts holding live terminals (IEC 60898-1)
600 VCTI targets in global OEM specifications
0.8 mmthe wall where UL 94 is now specified
ΔE ≤ 0.5colour tolerance Calco holds lot to lot

The job a breaker material does

Milliseconds to protect. Twenty years to stay safe.

When a fault comes, the MCB has milliseconds to trip, an arc to quench and a housing to keep whole, after years of heat cycling inside a closed distribution board. That makes the housing compound part of your safety case.

A material that sustains a flame, tracks under dust and humidity, or creeps away from a rivet turns a fault into a fire or a field failure. And your buyer wants the board to look like one product, in the grey or white of the range, lot after lot.

2023in series supply for breaker parts
100+successful trials on switchgear parts
25+grade and colour variants
EUbreaker grades exported to Europe since 2023

Figures are from Calco's own trial and inspection records. Every trial ran on the customer's own tool and press.

Inside the breaker

Six parts. One compound supplier.

Each part of a miniature circuit breaker sees a different mix of heat, arc, load and handling. Tap a part to see the grade matched to it.

What a breaker material lives through

Breakers are rated in amperes. Their plastics are qualified in degrees, volts and millimetres.

Rated where it fails

A rating on a 3.2 mm test bar says little about a 0.8 mm wall. Bars are drawn to scale.

3.2 mmUL test bar: what data sheets quote
1.5 mmtypical MCB housing wall
0.8 mmwhere global OEMs now rate, and where we test

The temperature ladder

Typical requirements in OEM specifications for parts in a breaker. Drag the temperature.

960°C

960 °C: glow-wire flammability for parts holding live parts in position.

  • 125 °C · ball pressure, live-part holders
  • 170 °C · heat deflection temperature
  • 650 °C · glow-wire flammability, other parts
  • 750–800 °C · glow-wire ignition target
  • 960 °C · glow-wire flammability, parts holding live parts

How breakers fail

Problem. Impact. What we do about it.

Problem

Glow-wire ignition at a loose terminal

Impact: fire risk. Fire spreads pole to pole across the board.

Calco fix

FR system built for GWFI 960 °C at thin walls. 960 °C GWFI at 1.6 and 3 mm in UL tests.

Problem

The rating only holds at 3.2 mm

Impact: type test fails, found only after the tool is cut.

Calco fix

Rated and verified at 0.8 mm. Passed at 0.8 mm where the incumbent failed.

Problem

Surface tracking between terminals

Impact: leakage, nuisance tripping, short circuit in the field.

Calco fix

High-CTI flame-retardant systems. 450 V CTI and 33.9 kV/mm dielectric strength, third-party tested.

Problem

Warpage and uneven shrinkage

Impact: case–cover gap, failed drop and IP tests.

Calco fix

Mineral-glass balance tuned per part. Matched the benchmark shrinkage in an OEM test, with no steel re-cut.

Problem

Colour off the OEM's plaque

Impact: a whole range rejected on ΔL alone.

Calco fix

Colour built on the FR base against your plaque: ΔL, Δa and Δb within 0.8, checked again after ageing.

Problem

Uncontrolled process change

Impact: audit non-conformances, traceability lost.

Calco fix

Management of change, QA-approved labels and 4M records. 12 of 12 audit points closed.

Our recommendation, part by part

The right grade for every part of the breaker.

ApplicationOur recommendationCalco gradesFamilyStatus
MCB / RCCB case and coverPA6, 20% mineral + 5% glass, FR: glow-wire, flat riveted shells, grey or white710C2383F4710C2383F2710C2383F2AFlamSaf®In production
Case and cover, mineral-onlyPA6, 20% mineral, FR: lowest warpage, light grey710C2283F4FlamSaf®In production
Isolator and changeover housingsAs the MCB range, colour-matched so a board reads as one product710C2383F4F6F9FlamSaf®In production
Arc-chamber surround and trip partsPA6, 20–25% glass, FR, V-0: stiffness and heat close to the arc710C2082F1710C2082F2710D2011FFlamSaf®In production
Switchgear and MCCB housingsPBT, 30% glass, FR, V-0: HDT up to 200 °C, low moisture, precise730C3381F730C3083F1730C3085F1ZiLITE®In production
Knobs, handles and terminalsUnfilled FR PA6 / PA66: toughness, snap and screw-torque strength710C0031F720C0031FFlamSaf®Ready to specify
Recycled-content housingsFR PA6 with post-industrial content, to OEM halogen-free specifications712D2088F-4712D2094F-4712D3081F2-4ReViveX®Ready to specify
UL-listed contactor and switchgear housingsPBT, 30% glass, FR, in UL file E541646731C3001FZiLITE®Ready to specify

Mineral-rich grades keep riveted shells flat; glass-rich grades take the heat around the arc chamber. UL 94 and glow-wire depend on thickness, so we test at your thinnest wall before the trial.

All flame-retardant grades in the grade finder

Measured, not claimed

The numbers behind our breaker grades.

From UL reports, third-party laboratories and OEM trials, not typical-value data sheets.

ReViveX® 712D2088F-4 vs incumbent · 0.8 mm

Head-to-head at an OEM

TestCalcoIncumbent
GWFI 960 °CPassFail
UL 94 V-2PassFail
Flexural modulus4,173 MPa4,054 MPa

ZiLITE® 731C3001F · UL file E541646

UL short-term tests

  • UL 94V-0 at 1.5 and 3.0 mm; 5VB at 3 mm
  • GWFI960 °C at 1.6 and 3 mm
  • GWIT650 °C at 1.6 mm; 800 °C at 3 mm
  • HAI150 arcs (PLC 0)
  • HWI42 s (PLC 2) at 3 mm

ZiLITE® 730C3083F · third-party, OEM-witnessed

Tracking and breakdown

CTI450 V
PLC 0 from600 V
Dielectric33.9 kV/mm
Typical spec30 kV/mm

CTI to IEC 60112; dielectric strength to IEC 60243-1.

Grade data by specification

The breaker range, side by side.

Values are the release windows in Calco's inspection standards. Every lot is tested against them before dispatch, so they are conservative compared with typical data-sheet values.

GradeConstructionUL 94HDT °CTensile MPaFlex mod. GPaDensity g/cc
710C2383F4PA6, 20% MF + 5% GF, FRV-2≥ 15060–804.5–5.51.35–1.41
710C2383F2PA6, MF + GF, FRV-2≥ 15060–903.0–4.01.34–1.38
710C2383F2AAs F4, high flowV-2≥ 15060–705.0–6.51.34–1.38
710C2383F6As F4, RAL-matchedV-2140–16060–804.0–6.01.35–1.40
710C2383F9As F4, RAL-matchedV-2140–16060–804.5–6.01.36–1.41
710C2283F4PA6, 20% mineral, FRV-2135–14565–754.0–6.01.31–1.35
710C2082F1F2PA6, 20% GF, FRV-0180–190110–1303.5–5.51.38–1.42
710C2311FPA6, 25% filled, FR, colourV-2140–15060–703.5–5.51.38–1.42
710D2011FPA6, 25% reinforced, FRV-2185–195105–1303.5–5.51.29–1.33
730C3381FPBT, 30% GF, FRV-0190–20080–1006.0–8.01.62–1.67
730C3083F1PBT, 30% GF, FR, light greyV-0190–200100–1206.0–10.01.62–1.66
730C3085F1PBT, 30% GF, FR, RAL 7012V-0180–200100–1205.0–7.01.62–1.66

Test methods: ASTM D638 (tensile at yield, 50 mm/min), ASTM D790 (flexural, 2 mm/min), ASTM D648 (HDT, 1.82 MPa, un-annealed), ASTM D792 (density); UL 94 at 3.2 mm. Source: Calco inspection standards. Values are specification windows and are not a guarantee of properties in a finished part.

The standards

The number your part has to hit.

The product standard, not the material data sheet, sets the glow-wire temperature. Parts that hold current-carrying parts in position are tested hotter than parts that do not.

ProductStandardParts holding live partsOther insulating parts
Miniature circuit breakersIEC 60898-1960 °C650 °C
RCCBs and RCBOsIEC 61008-1 / 61009-1960 °C650 °C
LV switchgear, contactors, MCCBsIEC 60947-1 / -2 / -4-1960 °C650 °C
Terminal blocksIEC 60947-7-1960 °C650 °C

Values summarise the usual requirement. Confirm against the current edition and clause of the standard your product is certified to.

Conversions

Where Calco took over from global grades.

Customer typeIncumbent materialCalco gradeResult
Indian switchgear OEMImported FR PBT730C3085F130% GF FR PBTIn series
OEM's moulderImported FR PBT730C3083F130% GF FR PBTIn series
Switchgear makerImported FR PA6710C2383F11F10In series
MCB makerImported FR PA6710C2383F2AIn series
MCB maker, RAL 7035Imported FR PA6710C2383F6In series
Switchgear makerIndian FR PA6710C2383F9F4In series
MCB brand, through its moulderImported PA6 MF/GF25710C2383F9In series

Customers are not named. Incumbent materials as recorded in Calco trial records. The Calco grade ran in the existing tool; changes, where needed, were to drying and melt settings only.

Try it on your own press.

A free 25 kg trial lot compounded on production lines, and a Calco engineer at your press to check glow-wire, fit and colour with you.

Request a sample