Keep the pack in its window.

An electric vehicle manages heat in more places than an engine ever did: battery, motor, inverter, charger and cabin all sit on one coolant network with valves, pumps, manifolds and chillers. Every wetted part sees hot glycol under pressure for the life of the vehicle, and that is exactly the environment in which hydrolysis-resistant CiLON® PA66 and NovaLYN™ mPPE have already proved themselves in radiator end tanks and cooling pipes.

What the material must deliver.

Glycol at temperature, for years

Property retention after coolant ageing is the pass mark; hydrolysis-resistant PA66 and mPPE are specified for it.

Burst and thermal cycling

Manifolds and connectors survive pressure cycling and –40 to +120 °C cycling without leak or creep.

Density and integration

mPPE is the lightest option; both families integrate ports, brackets and sensors into one moulding.

Welded and sealed

Vibration- and laser-weldable grades for two-shell manifolds; sealing surfaces held flat by low-warpage formulations.

Our recommendation, application by application.

ApplicationOur recommendationGrades to start fromFamilyStatus
Coolant manifolds and distribution blocksmPPE GF30, PA66 GF30 HR HS: no hydrolysis, burst after ageing620D3031720C3004 HSHDNovaLYN™ CiLON®In development
Battery chiller and cooling-plate connectorsPA66 GF30 HR, mPPE GF30: seal geometry held wet720C3004 HSHD620D3031CiLON® NovaLYN™In development
Electric water-pump and valve housingsmPPE GF30, PA66 GF30 HR: glycol at 100 °C for life620D3031720C3004 HSHDNovaLYN™ CiLON®In development
Thermostat and multi-way valve housingsPA66 GF30 HR HS: coolant ageing, creep at seals720C3004 HSHD720C3004 HSCiLON®Ready to specify
Radiator and chiller end tanksPA66 GF30 HR, mPPE GF30: proven crimp and burst life720C3004 HSHD620D3031CiLON® NovaLYN™In production
E-motor bearing cages and resolver holdersPA66 GF25–30 HS, PBT GF30: heat ageing, precision720C3004 HS730C3001CiLON® ZiLITE®In development
Inverter and e-axle sensor housingsPBT GF30, PBT GF30 FR: dimensional stability, V-0730C3001730C3001FZiLITE®In development
Cooling-fan modules for battery packsPA6 GF30 HF, mPPE GF30: flow for thin ribs, low inertia710C2031 HFHS620D3031CiLON® NovaLYN™Ready to specify

In production: grades in series supply for the named part. Ready to specify: validated grades with data sheets and trial quantities available; part-specific validation is run with you. In development: grades, colours and references being built with OEM and Tier-1 partners.

Design and development notes.

Validate on coolant, not water

Age test parts in the OEM's coolant at the specified concentration and temperature; glycol ageing is more severe than water for polyamide.

Weld-line strength governs burst

For welded manifolds, place gates so weld lines avoid ports and mounting bosses and validate burst pressure on welded assemblies.

Choose mPPE where the geometry moves

Where crimp seals or quick-connect geometry must not change with humidity, NovaLYN™ mPPE holds dimensions that polyamide cannot.

Supplied under IATF 16949.

PPAP documentation, IMDS material data and a test certificate with every lot.