At a glance.
- Family
- FlamSaf®
- Base polymer
- PA6
- Construction
- PA6, 25% reinforced, flame retardant
- Typical parts
- High-HDT trip and mechanism parts
- Features
- UL 94 V-2, HDT 185–195 °C
Not sure it fits?
Tell us the part and what it has to survive. We name one grade and the alternative.
Release window.
From Calco's inspection standard. Every lot is tested against these limits before dispatch.
| UL 94 | HDT °C | Tensile MPa | Flexural modulus GPa | Density g/cc |
|---|---|---|---|---|
| V-2 | 185–195 | 105–130 | 3.5–5.5 | 1.29–1.33 |
Test methods: ASTM D638 (tensile at yield, 50 mm/min), ASTM D790 (flexural, 2 mm/min), ASTM D648 (HDT, 1.82 MPa, un-annealed), ASTM D792 (density); UL 94 at 3.2 mm. Source: Calco inspection standards. Values are specification windows and are not a guarantee of properties in a finished part.
Typical starting conditions for moulding.
Starting points for standard reinforced grades. The grade data sheet and, where issued, the product-specific processing sheet take precedence: flame-retardant, high-flow and alloy grades run in narrower windows.
Documents for this grade.
Technical data sheet
Typical properties to ASTM and ISO methods, processing conditions and part-marking designation.
Safety data sheet
GHS format, built from the verified composition of the formulation.
Batch test certificate
Measured values against specification limits, issued with every lot.
Declarations
RoHS, REACH, IMDS data and recycled-content declarations where the grade requires them.
Related grades.
710C2383F4
PA6, 20% mineral + 5% glass fibre, flame retardant
Open710C2383F2A
PA6, mineral + glass fibre, flame retardant, high flow
Open710C2283F4
PA6, 20% mineral, flame retardant
Open710C2082F1 / 710C2082F2
PA6, 20% glass fibre, flame retardant
Open710C0031F / 710C0001F
PA6, unfilled, flame retardant, halogen free
OpenTry 710D2011F on your own press.
A free 25 kg trial lot compounded on production lines, and a Calco engineer at your press.