Calco Poly Technik

Home / Automotive / Under the hood / Fan and shroud

In production

Fan and shroud

The problem this part has to solve, what usually goes wrong, and the grade we recommend.

The problem your part has to solve.

The fan spins at several thousand rpm behind a radiator at 100 °C or more, so each blade root sees centrifugal and cyclic bending loads for hundreds of millions of cycles, and any warpage or moisture-driven dimensional change shows up as imbalance and noise. The shroud is a large, thin, ribbed part that carries the motor, seals to the radiator and must not resonate. Both must survive stone and debris impact and, increasingly, the added duty of cooling a battery pack.

Process: Injection moulding; hub overmoulded or pressed on the motor shaft.

What usually goes wrong

  • Blade-root fatigue cracking after long service or overspeed
  • Imbalance and noise from warpage, moisture uptake or inconsistent fill between blades
  • Shroud cracking at motor mounts and clips; resonance under vibration
  • Creep of the hub on the shaft; brittle failure on debris impact in the cold

Our recommendation.

For shrouds we recommend eCiLON® PA6 GF30, 711C3003: a black, cost-effective structural grade with the stiffness and impact strength the shroud needs and the lower footprint OEM programmes now ask for. Where the programme needs a declared recycled content, we propose the equivalent ReViveX® grade with 20% PIR; where ribs are thin and flow paths long, CiLON® PA6 GF30 HF HS, 710C2031 HFHS. For fan blades we recommend PA66 GF30, 721C3002 for fatigue performance and temperature margin. Where balance must hold across humidity, or where a lighter fan reduces motor load and inertia, we recommend NovaLYN™ mPPE GF30, 620D3031: near-zero moisture uptake, the lowest density, and dimensional stability that keeps the rotor true.

Why the Calco grade works

  • Fatigue performance from controlled fibre length and a matrix that stays tough after heat ageing
  • Dimensional stability for balance: mPPE option with near-zero moisture uptake
  • High flow for thin, deep blades and ribbed shrouds
  • Impact strength at –40 °C for debris and handling
  • Vibration resistance at the shroud mounts and clips

Which grade, when.

Choose whenCalco gradeConstructionFamilyWhat it gives you
Shrouds, structural, black, cost-effective711C3003PA6 GF30eCiLON®Stiffness, impact, lower footprint
Thin, deep ribs and long flow paths710C2031 HFHSPA6 GF30 HF HSCiLON®Flow and surface, heat stabilised
Fan blades, fatigue and temperature margin721C3002PA66 GF30eCiLON®Fatigue life, higher HDT
Balance across humidity, lowest inertia620D3031mPPE GF30NovaLYN™No moisture uptake, lowest density

How we validate it with you.

Fatigue and overspeed

Blade-root fatigue on moulded fans at temperature; overspeed burst to the OEM factor.

Balance dry and conditioned

Rotor balance measured dry-as-moulded and after conditioning to ISO 1110, and after heat ageing.

Modal and impact

Shroud modal survey against the operating range; debris impact at –40 °C on blades and shroud.

Try it on your own tool.

A free 25 kg trial lot compounded on production lines, and a Calco engineer at your press.